Intent: Reduce use of “long cycle” and finite raw materials. Implementation: Use rapidly renewable materials and products for 2.5% of total value of all building materials and products used (based on cost) harvested within a 10-year cycle or shorter consider: bamboo flooring wool cotton insulation cork flooring linoleum flooring wheat board cabinets straw board agrifiber […]
Posts Tagged ‘NCv2.2’
Materials and Resources 5.2 – Regional Materials – 20% Extracted, Processed & Manufactured Regionally
20% Extracted, Processed & Manufacturer Regionally Intent: Increase demand for building materials and products that are extracted and manufactured within the region. This supports indigenous resources and reduced environmental impacts from transportation. Implementation: Use materials that have been extracted, harvested, recovered or manufactured within 500 miles of the site Minimum 20% (based on cost) of […]
Materials and Resources 5.1 – Regional Materials – 10% Extracted, Processed & Manufactured Regionally
10% Extracted, Processed & Manufacturer Regionally Intent: Increase demand for building materials and products that are extracted and manufactured within the region. This supports indigenous resources and reduced environmental impacts from transportation. Implementation: Use materials that have been extracted, harvested, recovered or manufactured within 500 miles of the site Minimum 10% (based on cost) of […]
Innovation and Design Process 2 – LEED Accredited Professional
Easiest points in the book. Have a LEED-AP on the team, you gain this 1 point. Hopefully someday, it will be you earning a LEED project this one point in the near future! Good luck!!! Intent: To support and encourage the design integration required by a LEED for New Construction green building project and to […]
Innovation and Design Process 1.1 thru 1.4 – Innovation in Design
Intent: To provide design teams and projects opportunities for extra credit points or exceptional performance points for going above and beyond LEED for New Construction Green Building Rating System requirements. Implementation: Substantially exceed a LEED NC performance credit such as energy performance or water efficiency. Apply strategies that demonstrate a comprehensive approach and quantified environment […]
Indoor Environmental Air Quality 8.2 – Daylighting and Views – Views for 90% of Spaces
Intent: Provide connection between indoor and outdoor spaces through introduction of daylight and views into regularly occupied areas of the building. Implementation: Achieve direct line of site to outdoor for occupants in 90% of all regularly occupied areas glazing between 2′-6″ & 7′-6″ Plan View: area within sight lines drawing from perimeter vision glazing Section […]
Indoor Environmental Air Quality 8.1 – Daylighting and Views – Daylight 75% of Spaces
Intent: Provide connection between indoor and outdoor spaces through introduction of daylight and views into regularly occupied areas of the building. Implementation: OPTION 1 – GLAZING FACTOR CALCULATION achieve min. 2% glazing factor in minimum of 75% of regularly occupied areas. OPTION 2 – DAYLIGHT SIMULATION MODEL through computer simulation, demonstrate min. daylight illumination level […]
Indoor Environmental Air Quality 7.2 – Thermal Comfort – Verification
Intent: Assessment of building’s thermal comfort over time. Implementation: Survey within 6-18 months after occupancy anonymous responses of overall satisfaction of thermal performance If 20% or more of building occupants dissatisfied, develop a plan for corrective action Plan should be in accordance with ASHRAE 55-2004 Code: ASHRAE 55-2004: Thermal Comfort Conditions for Human Occupancy Submittal […]
Indoor Environmental Air Quality 7.1 – Thermal Comfort – Design
Intent: Provide a comfortable thermal environment supporting productivity and well-being of building occupants. Implementation: Design HVAC systems and Building Envelope per ASHRAE 55-2004. Evaluate air temp. radiant temp, air speed, relative humidity Coordinate with EQ P1. EQ 1, & EQ 2. Code: ASHRAE 55-2004: Thermal Comfort Conditions for Human Occupancy Submittal Phase: design Indoor Environmental […]
Indoor Environmental Air Quality 6.2 – Controllability of Systems – Thermal Comfort
Intent: Provide high level of thermal comfort system control for individuals and multi-occupant spaces to promote productivity, comfort and well being of building occupants. Implementation: Individual comfort controls for 50% min. of building occupants. Operable windows are OK instead if: occupants are stationed within 20′-0″ inside and 10′-0″ to either side of the window opening. […]